‰ NOW 25 WPM ‰ TEXT IS FROM NOVEMBER 2012 QST PAGE 65‰ CONDITION. THIS IS REPEATED 60 TIMES PER SECOND. THERE ARE THREE IMPORTANT THINGS TO NOTE ONE IS THAT THE OUTPUT VOLTAGE WAVEFORM IS NOT A PURE SINE WAVE, THE SECOND THING IS THE HOT AND NEUTRAL LEADS ARE NOT SWITCHED AT THE SAME TIME. THE THIRD THING IS THAT THERE IS LITTLE DIFFERENCE BETWEEN THE HOT AND NEUTRAL LEADS, BOTH ARE ACTUALLY HOT AND BOTH HAVE A LARGE COMMON MODE DC OFFSET IN ADDITION TO THE AC OUTPUT VOLTAGE. THE JOB OF A GFCI IS TO TRIP IF ANY OF THE CURRENT BEING SENT DOWN THE HOT LEAD TO A LOAD IS NOT RETURNING BY THE NEUTRAL LEAD, BECAUSE THIS MEANS THERE IS LEAKAGE SOMEWHERE, POSSIBLY THROUGH A PERSON. EVEN IN A HEALTHY POWER SYSTEM THERE IS ALWAYS SOME LEAKAGE CAUSED BY STRAY LINE TO GROUND CAPACITANCE AND ANY COMPONENTS INTENTIONALLY INSTALLED BETWEEN LINE AND GROUND, SUCH AS THOSE IN NOISE FILTERS AND SURGE PROTECTION. WITH COMMERCIAL POWER, THE SMALL VALUES OF LINE TO GROUND CAPACITANCE AND THE ‰ END OF 25 WPM TEXT ‰ QST DE W1AW ƒ