‰ NOW 30 WPM ‰ TEXT IS FROM OCTOBER 2017 QST PAGE 40‰ THE READING, BUT THE NUMBERS WOULD BE CORRECT. THIS IS FAR DIFFERENT FROM AN ANALOG METER, WHERE CONNECTING THE LEADS BACKWARDS MIGHT DAMAGE THE METER WHEN THE MOVING NEEDLE HITS THE RETAINING PIN ON THE METER FACE. THERE IS ONE MORE PROBLEM WITH THE METER ACCURACY, AS WITH ANY DIGITAL DEVICE DISPLAYING NUMBERS. THE METER IN FIGURE 10 IS DISPLAYING 9R21 V. THE LAST DIGIT IS ROUNDED OFF, JUST AS YOU MIGHT DO WHEN CALCULATING WITH PENCIL AND PAPER. THE ACTUAL VALUE MIGHT BE 9R210 OR PERHAPS 9R213, OR EVEN R208, BUT IS ROUNDED TO 9R21 V. WHILE THIS CAN SIMPLY BE AN ANNOYING PROBLEM, IT CAN ALSO BE A VERY SERIOUS ERROR IF THE METER SELECTS THE LOWEST POSSIBLE RANGE AND ONLY ONE SIGNIFICANT DECIMAL DIGIT IS SHOWING FOR EXAMPLE, 0R03 V. THEN YOU ARE NOT SURE IF THE TRUE NUMBER IS 0R02, 0R03, OR 0R04 V. OTHER FUNCTIONS THE MODEL SHOWN HERE HAS A BUILT IN BATTERY TESTER. SELECTING ONE OF THE FOUR BATTERY SCALES ALLOWS YOU TO PLACE THE LEADS ACROSS THE BATTERY UNDER ITS INSTALLED AND WORKING CONDITION, AND GET AN INDICATION OF THE BATTERYS CONDITION BY LOOKING AT THE THREE LEDS. GREEN MEANS OKAY, YELLOW MEANS QUESTIONABLE, AND RED MEANS FULLY ‰ END OF 30 WPM TEXT ‰ QST DE W1AW ƒ