‰ NOW 20 WPM ‰ DISCUSSED LATER. IT IS NOT GENERALLY A GOOD IDEA, AND MAY BE A VIOLATION OF YOUR BUILDING CODE. COUNT ON THE SAFETY GROUND TO KEEP YOU FROM GETTING A BAD SHOCK OR WORSE. DONT TRY TO CIRCUMVENT IT, BUT ESPECIALLY DONT TRY TO MAKE IT INTO SOMETHING IT ISNT A STATION GROUND. FINALLY THE STATION GROUND. WEVE DESCRIBED A FEW THINGS THAT ARENT A STATION GROUND. NOW LETS TRY TO FIND SOMETHING THAT IS. THE STATION GROUND SHOULD BE A SINGLE POINT AT WHICH ALL STATION EQUIPMENT GROUND TERMINALS CONNECT WITH AS SHORT A CONNECTION AS POSSIBLE. THIS POINT, IN TURN, SHOULD BE CONNECTED TO A DEDICATED EARTH GROUND SYSTEM THROUGH A VERY SHORT, LOW IMPEDANCE THICK, WIDE OR BOTH, LEAD. FIGURE 2 SHOWS A PROPERLY CONNECTED STATION GROUND ‰ FROM PAGE 97 ‰ K7ZD/340 K8AJR/339 K8AV/339 K8CH/360 K8DJC/345 K8FL/369 K8KAE/359 K8KWT/343 ‰ END OF 20 WPM TEXT ‰ QST DE W1AW ƒ