‰ NOW 20 WPM ‰ TEXT IS FROM JANUARY 2017 QST PAGE 32‰ GREATER PERCENTAGE OF ITS LENGTH SURROUNDED BY FERRITE CORE. BECAUSE THE CORE AREA IS DOUBLED, THE TURNS COUNT CAN BE HALVED. THIS CUTS LEAKAGE REACTANCE AND PARASITIC CAPACITANCE SOMEWHAT ALL TENDING IN THE RIGHT DIRECTION. SECOND, I SEPARATED THE PRIMARY FROM THE SECONDARY BY AN ELECTROSTATIC FARADAY SHIELD TO STOP ANY CAPACITIVE INTERACTION BETWEEN THE WINDINGS. THIRD, I DESIGNED THE SECONDARY WINDING TO A VOLTAGE THAT IS A FRACTION OF THE DESIRED OUTPUT VOLTAGE, AND THEN WOUND MULTIPLE SECONDARY WINDINGS BASED ON THE INVERSE OF THE FRACTION. THIS REDUCES LEAKAGE REACTANCE AND PARASITIC CAPACITANCE. EACH OF THE THREE 1100 V SECONDARY WINDINGS OPERATES INDEPENDENTLY, IS RECTIFIED AT EACH OUTPUT, AND SUMMED IN A SERIES CONNECTION TO GET THE DESIRED FULL OUTPUT. THIS ALSO AVOIDS ‰ END OF 20 WPM TEXT ‰ QST DE W1AW ƒ